European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery, Volume 67, Issue 1, 1 1 2024, Pages ezae414 Seven-year outcomes after surgical aortic valve replacement with a stented bovine pericardial bioprosthesis in over 1100 patients: a prospective multicentre analysis. Sabik JF, Rao V, Dagenais F, Moront MG, Reardon MJ, Patel HJ, Oh JK, Fukuhara S, Labrousse L, Günzinger R, Baig K, Ito S, Wu T, Klautz RJM, PERIGON Investigators

Objectives

Safety, efficacy and durability are important considerations when selecting a bioprosthesis for aortic valve replacement (AVR). This study assessed 7-year clinical outcomes and haemodynamic performance of the Avalus bioprosthesis.

Methods

Patients indicated for surgical AVR were enrolled in this prospective, nonrandomized trial, conducted across 39 sites globally. The primary end-point of this analysis was freedom from surgical explant or percutaneous valve-in-valve reintervention due to structural valve deterioration (SVD) at 7 years of follow-up, determined using Kaplan-Meier (KM) analysis. We also evaluated a composite end-point of SVD and/or severe haemodynamic dysfunction requiring reintervention. Survival, valve-related safety events and haemodynamic performance were assessed. Deaths and safety events were adjudicated by an independent clinical events committee.

Results

A total of 1132 patients underwent surgical AVR. Mean age was 70 years; 854 patients (75%) were men. The mean STS risk of mortality was 2.0 ± 1.4%, and 659 patients (58%) had a New York Heart Association classification of I/II. One or more concomitant procedures were performed in 577 patients (51%). At 7 years, the Kaplan-Meier rate of freedom from SVD/severe haemodynamic dysfunction requiring reintervention was 1.2% (0.5-2.5%) with no cases adjudicated as SVD. The survival rate was 82.6% (79.5-85.0%). The KM event rate was 5.7% (4.3-7.7%) for reintervention, 6.3% (4.9-8.3%) for endocarditis and 0.4% (0.1-1.1%) for valve thrombosis. Mean aortic gradient, dimensionless velocity index and effective orifice area were 13.8 ± 5.9 mmHg, 0.42 ± 0.09 and 1.99 ± 0.53 cm2, respectively.

Conclusions

This analysis demonstrated excellent durability of the Avalus valve with good clinical outcomes and stable haemodynamic performance through 7 years of follow-up.

Eur J Cardiothorac Surg. 2024 12;67(1):ezae414